GEP Breaktank Breaky 3 & 5

The security between the drink water supply and the indoor water network is sometimes legally mandatory. The EN1717 provides a number of technical possibilities. Using water of safety class 5, such as rainwater, grey water, stagnant water, or water of unknown origin is a “free range” mandatory.
The Breaktank Breaky 3 & 5 by GEP are conform to EN1717 and have a type AA disconnection. These break tanks are Belgaqua and KIWA certified. The Breaktanks Breaky 3 & 5 are equipped with a prefab installed self-priming pump. The pump is a pressure control so that pressure can be guaranteed on all disconnection points.

SKU: 405102 -405103 Categories: ,

Description

Application Area

The break tanks by GEP can be applied at installations where a short disconnection of the water network is requires or is mandatory. The most important reason to use a disconnection tank is to prevent the contamination of the water supply by the presence of substances in the event of back-flow of the water. This includes slaughterhouses, mortuaries, dentists, irrigation, laboratories, drinking water trays livestock, car washes, laundries etc. But break tanks are also used in systems with stagnant water such as sprinkler systems, extinguishing water, etc. Even in places
where they add substances to the water, such as antibiotics, one is obliged to place a disconnection tank between the drinking water supply and the indoor installation.

The GEP Breaktanks Breaky 3 & 5 are used in water systems where a normal domestic flow rate is required and where sometimes prolonged continues water usage can occur. Examples of these installations are in professional dishwashers, laboratories, small irrigation systems, slaughterhouses, etc.

The Breaktank Breaky 3 & 5 by GEP are equipped with a very small tank with a volume of 14 litres. The drinking water connection is located on the side of the unit and is conform to EN1717. This connection is Belgaqua and KIWA certified. The tank is equipped with a floater which makes sure that there is enough water in the tank. A prefab centrifugal pump is installed next to the tank, this is placed vertically which allows easy ventilation.

This pump ensures that the secundairy water network has a constant pressure by using a pressure control with dry run protection. Everything is prefab installed and removable for fast maintenance and service. The entire pump and break tank are covered with a stylish sound isolating cover. The system is suitable for wall installation. The GEP Breaktank Breaky 3 & 5 are delivered including complete connection set.

Options

The GEP Breaktanks Break 3 & 5 is available with different pumps in order to be able to realise different specific demands regarding pressure and capacity.

Technical Overview

Product benefits

Order Details

Art nrNAME (PG)
405102- GEP Breaktank Disconnection system Break 3 (1)

405103 – GEP Breaktank Disconnection system Break 5 (1)

Additional information

Weight 28 kg
Height in mm:

730 mm

Width in mm:

500 mm

Depth in mm:

235 mm

Drinking water connection:

DN1: 1" bi
DN2: 3/4"bi

RPM

2.900

Max. capacity

RC-3: 3,6 m³/h
RC-5: 5,4 m³/h

Max. Pressure in bar:

RC-3: 3,5 bar
RC-5: 5,2 bar

Temperature in Celcius:

5 – 35°C

Condensator

RC-3: 20 μF
RC-5: 25 μF

GEP Breaktank Breaky 3 & 5